FTS UK public procurement

Water Mist Suppression System Replacement

Transport for London

CompleteOCDS ID ocds-h6vhtk-051c5a
Tender value£2,962,1951 awards · 0 contracts

01 Procurement

Tender overview

Updated 31 March 2026
Buyer
Transport for London
Status
Complete
Procurement method
Below threshold - open competition
Category
works
CPV classification
Not supplied
Tender period
Not supplied — 24 November 2025

Description

The Water Mist Suppression and Sprinkler Systems requirement is for the procurement of a principal contractor to remove, replace and commission the Water Mist Suppression and Sprinkler Systems currently installed in 34 locations situated within 22 different London Underground stations. TfL's has identified that the fire suppression and sprinkler systems currently installed in the sites (Cleaner's Stores, Bin Stores, Stores and Retail Tenancies) are either life-expired, non-compliant or not fit for purpose under Article 5 of the Fire Precautions Sub-surface Railway Regulations 2009. It has also been identified that these systems do not have / meet the current applicable standards such as BS EN14279 and BS8489. The water mist systems have been installed on the TfL infrastructure in the early 1990's following the publication of the Fire Precautions Sub-surface Railway Regulations 1989 (updated 2009). The systems were installed where conventional sprinkler systems were not considered viable due to practical or logistical constraints and designed, installed and maintained in compliance with the American Standard NFPA750. Due to the increasing number, sizes, type of storage and trading activities within the network, further review of risks and tests for these suppression protection systems were undertaken and evaluated. This confirmed a requirement to replace these systems and design modern, compliant equivalent water mist system to replace the ageing noncompliant systems currently installed in the TfL LU estate. The modern systems will be tested by TfL to BS EN 14972-1 Annex A with a deluge time of not less than 60 minutes from the appropriate number of cylinders located locally, to provide reliable fire suppression to specific rooms identified. These new installations will be designed for but not limited to Cleaner's Stores, Bin Stores, Stores and Tenancies. In some cases, wet sprinklers systems extensions will replace the ageing Water Mist systems where they are available and economically viable.

i

This page represents one OCDS contracting process. Notices can be revised over time. Values may be estimates, award values or contract values and should be read with their displayed stage and date.

02 Awards and contracts

Published award records

1 shown
Cancelled

Water Mist Suppression System Replacement

Awarded
Not supplied
Award value
Not supplied
Suppliers
0
Signed contract
Not supplied

03 Organisations

Buyers, suppliers and other parties

1 parties
Buyer

Transport for London

5 Endeavour Square, London, UKI41, E20 1JN, United Kingdom

GB-PPON PHMT-6197-NWNZ

Companies House links appear only for explicit GB-COH identifiers. BritDB does not create company links from a similar name or address.

04 Provenance

Source for this process

Contains public sector information licensed under the Open Government Licence v3.0. Official external links are available only on the source transition page.