FTS UK public procurement

Atmospheric gas analyser

University Of Edinburgh

CompleteOCDS ID ocds-h6vhtk-06478f
Tender valueNot supplied2 awards · 2 contracts

01 Procurement

Tender overview

Updated 1 April 2026
Buyer
University Of Edinburgh
Status
Complete
Procurement method
Award procedure without prior publication of a call for competition
Category
goods
CPV classification
38344000 — Pollution-monitoring devices
Tender period
Not supplied — Not supplied

Description

SUMMARY The University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the <1 ppb for methane, <0.5 ppb for N2O and < 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz. PAYLOAD WEIGHT AND INTERFACE To enable use of the facility’s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg. MEASUREMENT APPROACH Measurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series. To give an example of the intention; At timestamp 1, a volume of air, V1, has been ‘ingested’, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1). At timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2). And so on, at the ‘Hz’ rating the device operates at. Measurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable. CONCLUSION After a market evaluation it is believed there is only one solution which can fulfil the combined requirements – the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons. Any suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication. Value represents cost excluding VAT and import duties (if applicable).

i

This page represents one OCDS contracting process. Notices can be revised over time. Values may be estimates, award values or contract values and should be read with their displayed stage and date.

02 Awards and contracts

Published award records

2 shown
Active

Atmospheric gas analyser

Awarded
Not supplied
Award value
Not supplied
Suppliers
1
Signed contract
4 February 2026
Active

Atmospheric gas analyser

Awarded
Not supplied
Award value
Not supplied
Suppliers
1
Signed contract
12 March 2026

03 Organisations

Buyers, suppliers and other parties

3 parties
Buyer, CentralPurchasingBody

University Of Edinburgh

Charles Stewart House, 9-16 Chambers Street, Edinburgh, UKM75, EH1 1HT, United Kingdom

ReviewBody

Edinburgh Sheriff Court

Edinburgh, United Kingdom

Supplier

GeoGas Analytica

Kneveloord 3, Balen, BE213, 2490, Belgium

Companies House links appear only for explicit GB-COH identifiers. BritDB does not create company links from a similar name or address.

04 Provenance

Source for this process

Contains public sector information licensed under the Open Government Licence v3.0. Official external links are available only on the source transition page.