Enforcement details
- Reference
- ENF-001748-02042025
- Record type
- Notice
- Action date
- 2 April 2025
- Result or notice type
- Improvement notice
- Offence or breach
- The cross cut saw is not fitted with an emergency stop that is able to bring the equipment to a safe condition in a safe manner once activated. As such there is a risk of serious personal injury, such as lacerations, as there is the potential for employees to come into contact with the blade if the machine cannot be stopped quickly when it is required. Compliance Date: 2025-06-02 Result: Complied With Acts or Regulations Breached: Provision and Use of Work Equipment Regulations 1998, 16 / 1; Health and Safety at Work etc Act 1974, 2 / 1
- Offence address
- Groesfaen Terrace, Bargod, CF81 9GH, Wales
- Recipient postcode
- CF47 0HU
- Region
- Wales
- Local authority
- Caerphilly UA
- Industry
- Manufacturing
- Main activity
- 16290 - Manufacture of other products of wood; manufacture of articles of cork, straw and plaiting materials
- Type of location
- Fixed
!
An enforcement-list record must be read in its official context. Verify the current HSE detail page before relying on outcome, status or monetary fields.